Pascal and Francis Bibliographic Databases

Help

Export

Selection :

Permanent link
http://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=14145704

Stimulus artifact removal using a software-based two-stage peak detection algorithm

Author
O'KEEFFE, Derek T1 ; LYONS, Gerard M1 ; DONNELLY, Alan E2 ; BYRNE, Ciaran A2
[1] Biomedical Electronics Laboratory, Department of Electronic and Computer Engineering, University of Limerick, Limerick, Ireland
[2] Department of Physical Education and Sports Science, University of Limerick, Limerick, Ireland
Source

Journal of neuroscience methods. 2001, Vol 109, Num 2, pp 137-145 ; ref : 22 ref

CODEN
JNMEDT
ISSN
0165-0270
Scientific domain
Neurology; Physiology, morphology
Publisher
Elsevier Science, Amsterdam
Publication country
Netherlands
Document type
Article
Language
English
Keyword (fr)
Algorithme Artefact Electromyographie Filtrage Logiciel Méthode essai Electrophysiologie Méthodologie
Keyword (en)
Algorithm Artefact Electromyography Filtering Software Test method Electrophysiology Methodology
Keyword (es)
Algoritmo Artefacto Electromiografía Filtrado Logicial Método ensayo Electrofisiología Metodología
Classification
Pascal
002 Biological and medical sciences / 002A Fundamental and applied biological sciences. Psychology / 002A25 Vertebrates: nervous system and sense organs / 002A25A General aspects. Models. Methods

Discipline
Vertebrates : nervous system and sense organs
Origin
Inist-CNRS
Database
PASCAL
INIST identifier
14145704

Sauf mention contraire ci-dessus, le contenu de cette notice bibliographique peut être utilisé dans le cadre d’une licence CC BY 4.0 Inist-CNRS / Unless otherwise stated above, the content of this bibliographic record may be used under a CC BY 4.0 licence by Inist-CNRS / A menos que se haya señalado antes, el contenido de este registro bibliográfico puede ser utilizado al amparo de una licencia CC BY 4.0 Inist-CNRS

Access to the document

Searching the Web