Influence of valve open timing and interval on performance of 4 K Gifford-McMahon cycle cryocooler

Author
LI, R1 ; ONISHI, A1 ; SATOH, T1 ; KANAZAWA, Y1
[1] Research and Development Center, Sumitomo Heavy Industries, Ltd., Yuhigaoka, Hiratsuka, Kanagawa, 254, Japan
Conference title
1995 Cryogenic Engineering Conference
Conference name
1995 Cryogenic Engineering Conference (Columbus, Ohio 1995-07-17)
Author (monograph)
KITTEL, Peter (Editor)1
[1] NASA-Ames Research Center, Moffett Field, California, United States
Source

Advances in cryogenic engineering. 1996, Vol 41, pp 1601-1607 ; B ; ref : 10 ref

CODEN
ACYEAC
ISSN
0065-2482
Scientific domain
Energy
Publisher
Plenum, London / Plenum, New York, NY
Publication country
United States
Document type
Conference Paper
Language
English
Keyword (fr)
Cryogénie Etude expérimentale Ouverture Performance Vanne Cryocooler Cycle Gifford McMahon
Keyword (en)
Cryogenics Experimental study Opening Performance Sluice
Keyword (es)
Criogenia Estudio experimental Abertura Rendimiento Compuerta
Classification
Pascal
001 Exact sciences and technology / 001D Applied sciences / 001D06 Energy / 001D06D Energy. Thermal use of fuels / 001D06D09 Refrigerating engineering. Cryogenics. Food conservation / 001D06D09B Cryogenics

Discipline
Energy
Origin
Inist-CNRS
Database
PASCAL
INIST identifier
3257826

Sauf mention contraire ci-dessus, le contenu de cette notice bibliographique peut être utilisé dans le cadre d’une licence CC BY 4.0 Inist-CNRS / Unless otherwise stated above, the content of this bibliographic record may be used under a CC BY 4.0 licence by Inist-CNRS / A menos que se haya señalado antes, el contenido de este registro bibliográfico puede ser utilizado al amparo de una licencia CC BY 4.0 Inist-CNRS

Access to the document

Searching the Web