kw.\*:("AIR NETWORK")
Results 1 to 25 of 37
Selection :
CONCEPTION, CONTROLE ET ENTRETIEN D'UNE INSTALLATION D'AIR COMPRIME-4LEFEVRE J.1983; EQUIPEMENT (L') INDUSTRIEL, ACHATS ET ENTRETIEN; ISSN 0396-6666; FRA; DA. 1983; VOL. 32; NO 351; PP. 43-52; 7 P.Article
LA METHODE DES Z EN CHAUFFAGE. APPLICATION A LA CLIMATISATION = THE Z METHOD IN HEATING TECHNIQUE. APPLICATION TO AIR CONDITIONINGLEROY R.1980; CHAUD FROID PLOMB.; FRA; DA. 1980; VOL. 34; NO 106; PP. 57-61Article
KANAELE UND ROHRE FUER LUFTTECHNISCHE ANLAGEN = DUCTS AND PIPES FOR AIR CONDITIONING PLANTS = CONDUITS ET TUYAUTERIES POUR INSTALLATIONS DE CONDITIONNEMENT D'AIR (SUITE ET FIN)MUERMANN H.1980; HAUSTECH. RDSCH.; DEU; DA. 1980; VOL. 79; NO 1; PP. 17-22; BIBL. 4 REF.Article
DESIGNING CONTROLLABLE HVAC PLANTS.LUSH DM.1977; BUILDG SERV. ENGR; G.B.; DA. 1977; VOL. 44; NO 11; PP. 235-249Article
LUFTVERTEILSYSTEME IN WARMLUFTHEIZUNGEN = AIR NETWORK IN HOT AIR HEATING SYSTEMS = LES SYSTEMES DE DISTRIBUTION DE L'AIR DANS LES INSTALLATIONS DE CHAUFFAGE PAR AIR CHAUDKOKOWSKI P.1980; K. I., KLIMA KAELTE HEIZ.; DEU; DA. 1980; VOL. 8; NO 2; PP. 55-58; ABS. ENG/FRE; BIBL. 1 REF.Article
LUFTSTROMABWEICHUNGEN BEI NICHT GELUNGENEM KANALNETZABGLEICH. = AIR STREAM PERTURBATIONS INDUCED BY UNPERFECT AIR NETWORK BALANCING = PERTURBATIONS DE L'ECOULEMENT DE L'AIR EN CAS D'EQUILIBRAGE DEFECTUEUX DU RESEAU D'AIRLEINER W; HOLINER R.1978; KLIMA+KAELTE INGR; DTSCH.; DA. 1978; VOL. 6; NO 5; PP. 187-192; ABS. ANGL. FR.; BIBL. 2 REF.Article
CALCULS ECONOMIQUES DES RESEAUX AERAULIQUES. = ECONOMIC CALCULATION OF AIR NETWORKS1976; PROMOCLIN B; FR.; DA. 1976; VOL. 7; NO 10; PP. 469-492Article
COMPUTER ANALYSIS OF DUCT SYSTEMSHUTT B.1979; HEATG AIR CONDITIONG J.; GBR; DA. 1979; VOL. 49; NO 573; PP. 12-16; (3 P.)Article
CALCUL DES PERTES DE CHARGE: LES RESEAUX D'AIR. 16. INSTALLATIONS DE VENTILATION ET DE CONDITIONNEMENT D'AIR = PRESSURE DROP CALCULATIONS: AIR NETWORKS. 16. VENTILATING AND AIR CONDITIONING INSTALLATIONSBOUSSICAUD A.1979; CHAUD FROID PLOMB.; FRA; DA. 1979; VOL. 33; NO 396; PP. 103-116Article
UNTERSTUETZUNG BEI ANLAGENPLANUNG DER TECHNISCHEN GEBAEUDE AUSRUETUNG DURCH SPEICHERUNG VON BAUPRODUKTIONFORMATIONEN. = ASSISTANCE FOR BUILDING SERVICES PLANING BY TECHNICAL DATA STORAGE = ASSISTANCE A L'ETUDE DES EQUIPEMENTS TECHNIQUES DE BATIMENTS PAR LE STOCKAGE D'INFORMATIONS SUR LES PRODUITS POUR BATIMENTSKRESIC MJ.1977; H.L.H.; DTSCH.; DA. 1977; VOL. 28; NO 12; PP. 455-458; ABS. ANGL.Article
CONSIDERAZIONI TECNICO ECONOMICHE SUI CONDOTTI DI VENTILAZIONE. 1. = ECONOMICAL AND TECHNICAL REMARKS ON VENTILATION DUCTS = CONSIDERATIONS TECHNIQUES ET ECONOMIQUES SUR LES CONDUITS DE VENTILATIONLESSIEUR PD.1976; INSTALLATORE ITAL.; ITAL.; DA. 1976; VOL. 27; NO 9; PP. 779-800; ABS. FR. ANGL. ALLEM.Article
DIE DIMENSIONIERUNG VON GLEICHFOERMIGEN ABLUFTKANALNETZEN UNTER VERWENDUNG VON KANALDUESEN. II: EXPERIMENTELLE ERGEBNISSE = SIZING OF UNIFORM AIR DUCT NETWORKS FITTED WITH NOZZLES. II. EXPERIMENTAL RESULTS = LE DIMENSIONNEMENT DES RESEAUX DE CANALISATIONS UNIFORMES MUNIS DE TUYERES POUR L'EVACUATION DE L'AIR. II. RESULTATS EXPERIMENTAUXPRESSER KH.1979; G.I. HAUSTECH. BAUPHYS. UMWELTTECH.; DEU; DA. 1979; VOL. 100; NO 12; PP. 361-370Article
EXISTING BUILDING THEORETICAL ENERGY CONSUMPTION ANALYSIS - FACT OF FICTION.1977; A.S.H.R.A.E. TRANS.; U.S.A.; DA. 1977; VOL. 83; NO 1; PP. 551-577; BIBL. DISSEM.Article
LES RESEAUX AERAULIQUES: LEUR CONSTRUCTION! LEUR NORMALISATION = AIR NETWORK: CONSTRUCTION. STANDARDIZATIONRUBIN RL.1981; HEIZUNG UND LUEFTUNG; ISSN 0251-1231; CHE; DA. 1981; VOL. 48; NO 6; PP. 17-24Article
UN RESEAU DE V.M.C. PREREGLE EN USINE: MISE EN OEUVRE, CONTROLE DES RESULTATS = A CONTROLLED MECHANICAL VENTILATION DUCTWORKROUSSEL M.1980; CHAUFF. VENT., COND.; ISSN 0009-2029; FRA; DA. 1980; VOL. 56; NO 10; PP. 11-17Article
VERTEILNETZE-DRUCKVERLUSTBERECHNUNG FUER WARMWASSER- UND RAUMLUFT TECHNISCHE ANLAGEN = DISTRIBUTION OUTWORKS. CALCULATION OF PRESSURE LOSS IN HOT WATER HEATING AND AIR CONDITIONING SYSTEMS = RESEAUX DE DISTRIBUTION. CALCUL DES PERTES DE CHARGE POUR LES INSTALLATIONS DE CHAUFFAGE PAR EAU CHAUDE ET DE CONDITIONNEMENT D'AIRIHLE C.1980; OEL-GASFEUER.; ISSN 0029-8662; DEU; DA. 1980; VOL. 25; NO 10; PP. 573-580; 6 P.; BIBL. 2 REF.Article
LES POMPES A CHALEUR DANS L'HABITAT NEUF = THE HEAT PUMP IN NEW RESIDENTIAL BUILDINGSSETA P; BERHONDO P; ODDOU J et al.1981; REVUE GENERALE DE THERMIQUE; ISSN 0035-3159; FRA; DA. 1981; VOL. 20; NO 236-237; PP. 629-647Article
THE MUTUAL INTERFERENCE OF ENERGY LOSSES IN THE RIGHT ANGLED BRANCH PIPE LINE.HOSOKAWA Y; MORIKAWA Y.1975; TRANS. S.H.A.S.E. JAP.; JAP.; DA. 1975; VOL. 13; PP. 31-43; BIBL. 9 REF.Article
The economics of VAV duct looping. Connecting duct system ends to let underutilized ducts help those fully loaded can offer savings well worth pursuingCOE, P. E. JR.Heating, piping and air conditioning. 1983, Vol 55, Num 8, pp 61-64, issn 0017-940XArticle
The hub network design problem with stopovers and feeders: the case of Federal expressKUBY, M. J; GRAY, R. G.Transportation research. Part A, Policy and practice. 1993, Vol 27, Num 1, pp 1-12, issn 0965-8564Article
Criteri di realizzazione dei canali d'aria per impianti di condizionamento = Criteria for the construciton of air pipes for conditioning systemsCHIESA, M.Installatore italiano. 1992, Vol 43, Num 10, pp 1697-1705, issn 0020-2118Article
Un nouveau terminal de «clim» combine débit d'air variable et induction = A new an-conditioning terminal combines variable air flow and inductionCFP. Chaud froid plomberie. 2001, Num 634, pp 57-60, issn 0750-1552Article
Réseaux aérauliques : transformation de la pression dynamique en pression statique = Ventilation networks : converting dynamic pressure into static pressureCFP. Chaud froid plomberie. 2000, Num 630, pp 69-73, issn 0750-1552Article
Dimensionnement et technologie des réseaux d'air comprimé = Dimensioning and technology of compressed air networksROUMAJON, J.CFP. Chaud froid plomberie. 1997, Num 595, pp 105-114, issn 0750-1552Article
Calculs acoustiques dans les réseaux d'air = Acoustic calculations in air networksBASTIDE, N.CFP. Chaud froid plomberie. 1995, Vol 49, Num 573, pp 113-118, issn 0750-1552Article