Pascal and Francis Bibliographic Databases

Help

Search results

Your search

au.\*:("BORCKE E")

Publication Year[py]

A-Z Z-A Frequency ↓ Frequency ↑
Export in CSV

Discipline (document) [di]

A-Z Z-A Frequency ↓ Frequency ↑
Export in CSV

Language

A-Z Z-A Frequency ↓ Frequency ↑
Export in CSV

Results 1 to 11 of 11

  • Page / 1

Export

Selection :

  • and

ANFERTIGEN VON BILDERN IN DER DURCHSTRAHLUNGSPRUEFUNG AUF FOTOPAPIER = OBTENTION D'IMAGES SUR PAPIER PHOTOGRAPHIQUE LORS DU CONTROLE PAR RADIOGRAPHIEBORCKE E.1980; MASCHINENMARKT; ISSN 0025-4509; DEU; DA. 1980; VOL. 86; NO 8; PP. 126-128Article

BILDGRITEUNTERSUCHUNG ZUR DIREKTEN ROENTGENOLOGISCH VERGROESSERUNG = ETUDE DE LA QUALITE DE L'IMAGE PAR AMPLIFICATION RADIOLOGIQUE DIRECTEFRANKEN T; BORCKE E.1980; FORTSCHR. GEB. ROENTGENSTRAHL. NUKLEARMED.; DEU; DA. 1980; VOL. 132; NO 3; PP. 320-325; ABS. ENG; BIBL. 33 REF.Article

RADIOGRAPHIE QUANTITATIVE DES OSBORCKE E; HEUCK F.1975; BULL. RADIOGR.; BELG.; DA. 1975; NO 22; PP. 3-9Article

Die Qualität im Röntgenbild - Ein Vorschlag für eine Quantifizierung der Bildqualität = La qualité des images RX en radiographie. Un essai de quantification de la qualité des images = XR images quality. Assay of quantification of image qualityBORCKE, E.Röntgen-Blätter. 1987, Vol 40, Num 1, pp 18-22, issn 0300-8592Article

ZUM INFORMATIONSUMFANG DES DURCHSTRAHLUNGSBILDES BEI DICKENUNTERSCHIEDEN DES OBJEKTES = LATITUDE D'INFORMATION DE L'IMAGE RADIOGRAPHIQUE DANS LE CAS D'UN OBJET A EPAISSEUR VARIABLEBORCKE E; ROBAKOWSKI D; WEIGAND H et al.sdEUROPAEISCHE TAGUNG FUER ZERSTOERUNGSFREIE PRUEFUNG/1981/WIEN; AUT; DA. S.D.; PP. 61-62; ABS. ENG/FREConference Paper

Überprüfung der Computeranssagen eines neuartigen Systems zur Bestimmung der Bildqualität (QWS) an natürlichen Fehlern bei Schweissnähten = Vérification des données informatisées d'un nouveau système d'évaluation de la qualité d'image dans le cas de défauts naturels dans les soudures = Checking of the computer data in a new image quality assessment system for natural weld defectsBORCKE, E; FISCHER, K. H.Nondestructive testing. European conference. 1984, pp 507-523Conference Paper

Überprüfung der Computeraussagen eines neuartigen Systems zum Bestimmen der Bildgüte an natürlichen Fehlern bei Schweissnähten = Vérification des résultats fournis par l'ordinateur lors de l'utilisation d'un nouveau système d'évaluation de la qualité d'image de défauts de soudures réels = A check of computer-produced results from a new system for determining image quality from natural flaws in weldsBORCKE, E; FISCHER, K.-H.Schweissen + Schneiden. 1986, Vol 38, Num 2, pp 76-79, issn 0036-7184Article

RATIONALISIERUNG BEI DER DURCHSTRAHLUNGSPRUEFUNG = RATIONALISATION DES ESSAIS RADIOGRAPHIQUESKRUEGER G; BORCKE E; ROBAKOWSKI D et al.1979; MATERIALPRUEFUNG; DEU; DA. 1979; VOL. 21; NO 10; PP. 366-368Article

RADIOGRAPHY: IMAGE QUALITY. = RADIOGRAPHIE: QUALITE D'IMAGERUAULTS PA; PROEGLER H; KRASKE W et al.1976; IN: 8EME CONF. MONDIALE ESSAIS NON DESTRUCT.; CANNES; 1976; PARIS; C.O.F.R.E.N.D.; DA. 1976; PP. (82P.); ABS. FR.; BIBL. DISSEM.; SECTION 3EConference Paper

Der Einfluss der Betrachtungszeit auf die Wahrnehmung von Details im Röntgenbild = L'influence du temps d'observation sur la perception des détails des radiographies = Influence of observation time on perception of radiographic detailOESTMANN, J. W; BORCKE, E; VON BOEHMER, H et al.RöFo. Fortschritte auf dem Gebiete der Röntgenstrahlen und der Nuklearmedizin. 1988, Vol 148, Num 3, pp 314-318, issn 0340-1618Article

Sicherung der Bildqualität in röntgendiagnostischen Betrieben. Informationen zur Normenreihe DIN 6868 = Assurance de la qualité de l'image en pratique radiologique diagnostique. Informations sur la série de normes DIN 6868 = Image quality assurance in X-ray diagnostics. Information on DIN-standard 6868BECKER-GAAB, C; BORCKE, E; WIDENMANN, L et al.Der Radiologe (Berlin. Print). 1985, Vol 25, Num 11, pp 529-533, issn 0033-832XArticle

  • Page / 1