Pascal and Francis Bibliographic Databases

Help

Search results

Your search

kw.\*:("CAMERA SCINTILLATION")

Document Type [dt]

A-Z Z-A Frequency ↓ Frequency ↑
Export in CSV

Publication Year[py]

A-Z Z-A Frequency ↓ Frequency ↑
Export in CSV

Discipline (document) [di]

A-Z Z-A Frequency ↓ Frequency ↑
Export in CSV

Language

A-Z Z-A Frequency ↓ Frequency ↑
Export in CSV

Author Country

A-Z Z-A Frequency ↓ Frequency ↑
Export in CSV

Results 1 to 25 of 220

  • Page / 9
Export

Selection :

  • and

A VARIABLE ANGLE SLANT-HOLE COLLIMATORMOORE RH; ALPERT NM; STRAUSS HW et al.1983; JOURNAL OF NUCLEAR MEDICINE; ISSN 0022-3123; USA; DA. 1983; VOL. 24; NO 1; PP. 61-65; BIBL. 16 REF.Article

CAMERA A POSITION PAR UTILISATION D'UN DETECTEUR FOCAL A MULTICRISTAUX HEXAGONAUXTOMITANI T; TANAKA E; NOHARA N et al.1976; RADIOISOTOPES; JAP.; DA. 1976; VOL. 25; NO 11; PP. 693-698; ABS. ANGL.; BIBL. 5 REF.Article

LA SCINTIGRAPHIE DYNAMIQUE DU SYSTEME HEPATO-BILIAIREGABUNIYA RI; BERDOV BA; TSYPLYAEV VA et al.1976; MED. RADIOL.; S.S.S.R.; DA. 1976; VOL. 21; NO 4; PP. 26-31; ABS. ANGL.; BIBL. 10 REF.Article

ETUDE SUR UNE GAMMA-CAMERA A TUBES AMPLIFICATEURS DE LUMINANCECHARDON R.1973; DGRST-7270478; FR.; DA. 1973; PP. (19P.); (RAPP. FINAL, ACTION CONCERTEE: GENIE BIOL. MED.)Report

PERFORMANCE OF SCINTILLATION CAMERASHINE GJ; PARAS P.1975; J. NUCL. MED.; U.S.A.; DA. 1975; VOL. 16; NO 12; PP. 1206-1207Article

MESURE DES TEMPS DE RESOLUTION D'UNE CAMERA A SCINTILLATIONS ET CHOIX D'UNE METHODE DE CORRECTION DES PERTES DE COMPTAGEKOUCAYROL JC; COMET M; DEVAUX JY et al.1975; ANN. PHYS. BIOL. MED.; FR.; DA. 1975; VOL. 9; NO 1; PP. 1-17; ABS. ANGL.; BIBL. 17 REF.Article

SCINTIGRAPHIE DU FOIE AVEC LA CAMERA A SCINTILLATION; COMPARAISON AVEC LE COLLOIDE SN-99MTC ET PHYTATE-99MTCABURANO T; UENO K; WATANABE H et al.1974; RADIOISOTOPES; JAP.; DA. 1974; VOL. 23; NO 7; PP. 391-394; ABS. ANGL.; BIBL. 11REF.Article

QUALITY ASSURANCE OF SCINTILLATION CAMERAS. AN IMPLEMENTATION PROGRAMBUCHER JE; VAN TUINEN RJ; MOORE MM et al.1975; J. NUCL. MED. TECHNOL.; U.S.A.; DA. 1975; VOL. 3; NO 2; PP. 87-90; BIBL. 5 REF.Article

MESURE DU DEBIT CARDIAQUE AVEC UNE CAMERA A SCINTILLATION COUPLEE A UN SYSTEME DE STOCKAGE ET DE TRAITEMENT DE L'INFORMATIONROUCAYROL JC; COMET M; DEVAUX JY et al.1975; ANN. PHYS. BIOL. MED.; FR.; DA. 1975; VOL. 9; NO 3; PP. 183-191; ABS. ANGL.; BIBL. 9 REF.Article

THE LOW-TEMPERATURE SCINTILLATION PROPERTIES OF BISMUTH GERMANATE AND ITS APPLICATION TO HIGH-ENERGY GAMMA RADIATION IMAGING DEVICESPILTINGSRUD HV.1979; J. NUCL. MED.; USA; DA. 1979; VOL. 20; NO 12; PP. 1279-1285; BIBL. 7 REF.Article

LARGE-FIELD-OF-VIEW (LFOV) SCINTILLATION CAMERAS.MURPHY PH; BURDINE JA.1977; SEMINARS NUCL. MED.; U.S.A.; DA. 1977; VOL. 7; NO 4; PP. 305-313; BIBL. 20 REF.Article

SCINTILLATION CAMERA VERSUS RECTILINEAR SEANNER FOR LIVER IMAGING.TURNER DA; OSTER ZH.1976; J. NUCL. MED.; U.S.A.; DA. 1976; VOL. 17; NO 5; PP. 419-421; BIBL. 9 REF.Article

SYSTEME DE MARQUAGE POUR CAMERA A SCINTILLATION ET ORDINATEUR, APPLICATION CLINIQUENARABAYASHI I; ITO K; YOSHIDA S et al.1976; RADIOISOTOPES; JAP.; DA. 1976; VOL. 25; NO 3; PP. 147-152; ABS. ANGL.; BIBL. 4 REF.Article

APPLICATION OF THE SCINTILLATION CAMERA TO THE RADIOCHROMATOGRAMENGLISH RJ.1976; J. NUCL. MED. TECHNOL.; U.S.A.; DA. 1976; VOL. 4; NO 2; PP. 80-82; BIBL. 4 REF.Article

DYNAMIC IMAGING OF THE RESPIRATORY CYCLE WITH 81MKRKAPLAN E; GERGANS GA; MILO T et al.1982; CHEST; ISSN 0012-3692; USA; DA. 1982; VOL. 81; NO 3; PP. 312-317; BIBL. 15 REF.Article

PERFORMANCE CHARACTERISTICS OF A COMMERCIAL ECG GATEGRAHAM M; CAVAILLOLES F; RITCHIE JL et al.1980; J. NUCL. MED.; USA; DA. 1980; VOL. 21; NO 4; PP. 387-390; BIBL. 3 REF.Article

USE OF THE ANGER SCINTILLATION CAMERA FOR DETERMINING THYROID UPTAKEVERDON TA; MCCOWEN KD; HOFELDT FD et al.1976; J. NUCL. MED.; U.S.A.; DA. 1976; VOL. 17; NO 5; PP. 359-361; BIBL. 6 REF.Article

COMPARISON OF 5: 1 RECTILINEAR SCANS WITH SCINTILLATION CAMERA IMAGES IN BONE SCANNINGMANDELL CH; HOULE HM.1975; J. NUCL. MED. TECHNOL.; U.S.A.; DA. 1975; VOL. 3; NO 1; PP. 43-44; BIBL. 1REF.Article

EIN UNGEWOEHNLICHES SZINTIGRAPHISCHE BILD BEI LEBERZIRRHOSE = UNE IMAGE SCINTIGRAPHIQUE RARE DANS LA CIRRHOSE HEPATIQUEDRESSLER J; KRAMANN B.1975; FORTSCHR. GEB. ROENTGENSTRAHL. NUKLEARMED.; DTSCH.; DA. 1975; VOL. 122; NO 2; PP. 174-175; BIBL. 9REF.Article

DIAGNOSTIC ISOTOPIQUE DES THROMBOSES PERIPHERIQUESCORNU P; SCALET M.1975; REV. FR. MAL. RESP.; FR.; DA. 1975; VOL. 3; SUPPL. 1; PP. 127-138; ABS. ANGL.; BIBL. 20 REF.Article

BONE MINERAL CONTENT DETERMINED BY FUNCTIONAL IMAGING = TENEUR DE L'OS EN MINERAUX DETERMINEE PAR VISUALISATION FONCTIONNELLEDEPUEY EG; THOMPSON WL; ALAGARSAMY Y et al.1975; J. NUCL. MED.; U.S.A.; DA. 1975; VOL. 16; NO 10; PP. 891-895; BIBL. 12 REF.Article

BREVET 2.336.112 (A1) (76 38558). - 21 DECEMBRE 1976. COLLIMATEUR POUR CAMERA A SCINTILLATION.sdPatent

CLINICAL SIGNIFICANCE OF SCINTILLATION CAMERA ELECTRONICS CAPABLE OF HIGH PROCESSING RATES.MURPHY P; ARSENEAU R; MAXON E et al.1977; J. NUCL. MED.; U.S.A.; DA. 1977; VOL. 18; NO 2; PP. 175-179; BIBL. 6 REF.Article

DETERMINATION DU TEMPS DE TRANSIT MOYEN HEPATIQUE AU COURS DES CIRRHOSES AU MOYEN DE LA CINEGAMMAGRAPHIE SPLENO-PORTALE.PARAF A; SYROTA A; VINOT JM et al.1977; MED. CHIR. DIGEST.; FR.; DA. 1977; VOL. 6; NO 4; PP. 191-192; BIBL. 1 REF.Article

LOCALIZATION OF MYOCARDIAL DISORDERS OTHER THAN INFARCTION WITH 99MTC-LABELED PHOSPHATE AGENTSPEREZ LA; HAYT DB; FREEMAN LM et al.1976; J. NUCL. MED.; U.S.A.; DA. 1976; VOL. 17; NO 4; PP. 241-246; BIBL. 12 REF.Article

  • Page / 9