Pascal and Francis Bibliographic Databases

Help

Search results

Your search

kw.\*:("CONFIGURATION TIGE TIGE")

Document Type [dt]

A-Z Z-A Frequency ↓ Frequency ↑
Export in CSV

Publication Year[py]

A-Z Z-A Frequency ↓ Frequency ↑
Export in CSV

Discipline (document) [di]

A-Z Z-A Frequency ↓ Frequency ↑
Export in CSV

Language

A-Z Z-A Frequency ↓ Frequency ↑
Export in CSV

Author Country

A-Z Z-A Frequency ↓ Frequency ↑
Export in CSV

Results 1 to 21 of 21

  • Page / 1
Export

Selection :

  • and

MECANISMES DE DISRUPTION DANS DE LONGS INTERVALLES D'AIR SOUMIS A DES IMPULSIONS DE COMMUTATIONWADA S.1972; RES. ELECTROTECH. LAB.; JAP.; DA. 1972; NO 727; PP. 1-113; ABS. ANGL.; BIBL. 2 P.Serial Issue

DIAGRAMME OPTIQUE DES DECHARGES ELECTRIQUES DANS UN INTERVALLE D'AIR LIMITE PAR DES DIELECTRIQUESBAGIROV MA; KURBANOV MA; NURALIEV N EH et al.1972; ELEKTRON. OBRABOT, MATER., MOLDAV. S.S.R.; S.S.S.R.; DA. 1972; NO 2; PP. 9-12; BIBL. 5 REF.Serial Issue

NEUE ERKENNTNISSE UEBER DEN LICHTBOGENSCHUTZ. = NOUVELLES CONNAISSANCES SUR LA PROTECTION CONTRE LES ARCS ELECTRIQUESKLAY H.1977; BULL. ASS. SUISSE ELECTRICIENS; SUISSE; DA. 1977; VOL. 68; NO 12; PP. 582-584; ABS. FR.; BIBL. 1 REF.Article

BREAKDOWN PHENOMENA OF ROD-ROD GAPS UNDER IMPULSE VOLTAGES OF OPPOSITE POLARITY ON BOTH ELECTRODES.ZACKE P; FISCHER A; BOECKER H et al.1977; I.E.E.E. TRANS. POWER APPAR. SYST.; U.S.A.; DA. 1977; VOL. 96; NO 2; PP. 701-708; BIBL. 2 REF.Article

BREAKDOWN OF SERIES-CONNECTED AIRGAPSSTEEL JG; WHITTINGTON HW.1972; PROC. INSTIT. ELECTR. ENGRS; G.B.; DA. 1972; VOL. 119; NO 10; PP. 1526-1528; BIBL. 5 REF.Serial Issue

INFLUENCE OF THE WAVEFRONT OF IMPULSE VOLTAGES ON THE SPARKOVER OF ROD GAPS AND INSULATORS.ALLIBONE TE; DRING D.1975; PROC. INSTIT. ELECTR. ENGRS; G.B.; DA. 1975; VOL. 122; NO 2; PP. 235-238; BIBL. 16 REF.Article

CARACTERISTIQUES STATISTIQUES DE LA DUREE PRECEDANT LA NAISSANCE DE DENDRITES DANS L'ISOLATION DU POLYETHYLENELAPSHIN VA; LYSAKOVSKIJ GG.1977; IZVEST. VYSSH. UCHEBN. ZAVED., ENERGET.; S.S.S.R.; DA. 1977; VOL. 20; NO 12; PP. 40-45; BIBL. 7 REF.Article

INFLUENCE OF HUMIDITY ON THE BREAKDOWN OF SPHERE AND ROD GAPS UNDER IMPULSE VOLTAGES OF SHORT AND LONG WAVEFRONTSALLIBONE TE; DRING D.1972; PROC. INSTIT. ELECTR. ENGRS; G.B.; DA. 1972; VOL. 119; NO 9; PP. 1417-1422; BIBL. 13 REF.Serial Issue

INFLUENCE OF HUMIDITY ON THE SPARKOVER OF ROD-ROD GAPS OF SEVERAL GEOMETRICAL FORMS SUBJECTED TO POSITIVE IMPULSE VOLTAGES OF VARYING WAVESHAPESALLIBONE TE; DRING D; ALLEN NL et al.1979; PROC. INSTIT. ELECTR. ENGRS; GBR; DA. 1979; VOL. 126; NO 5; PP. 462-466; BIBL. 12 REF.Article

VLIV VLHKOSTI NA PRESKOKOVE NAPETI JISKRIST' A TYCOVYCH IZOLATORU = L'INFLUENCE DE L'HUMIDITE SUR LA TENSION D'AMORCAGE DES ECLATEURS ET DES ISOLATEURS A TIGESCHUBERT H; BERAN J; KUCERA J et al.1979; ELECTROTECH. OBZOR; CSK; DA. 1979; VOL. 68; NO 1; PP. 3-6; ABS. RUS/FRE/GER/ENG; BIBL. 4 REF.Article

AC CORONA AND BREAKDOWN CHARACTERISTICS FOR ROD GAPS IN COMPRESSED HYDROGEN, SF6 AND HYDROGEN-SF6 MIXTURES.COOKSON AH; WOOTTON RE.1978; I.E.E.E. TRANS. POWER APPAR. SYST.; USA; DA. 1978; VOL. 97; NO 2; PP. 415-423; BIBL. 18 REF.Article

SPARKOVER OF ROD GAPS STRESSED WITH IMPULSE VOLTAGES OF NONSTANDARD WAVESHAPES.ALLIBONE TE; DRING D; DRAGAN G et al.1975; PROC. INSTIT. ELECTR. ENGRS; G.B.; DA. 1975; VOL. 122; NO 5; PP. 581-584; BIBL. 11 REF.Article

IMPULSE FLASHOVER CHARACTERISTICS OF LONG AIR GAPS AND ATMOSPHERIC CORRECTION.AIHARA Y; HARADA T; AOSHIMA Y et al.1978; I.E.E.E. TRANS. POWER APPAR. SYST.; U.S.A.; DA. 1978; VOL. 97; NO 2; PP. 342-348; BIBL. 15 REF.Article

DIE VORENTLADUNGS-STABILISIERTE DURCHSCHLAGSPANNUNG IN LUFT UND SF6. = LA TENSION D'AMORCAGE DANS L'AIR ET L'HEXAFLUORURE DE SOUFRE STABILISEE PAR LA PREDECHARGEMAZEN ABDEL SALAM.1978; ELEKTROTECH. Z., A; DTSCH.; DA. 1978; VOL. 99; NO 5; PP. 271-275; ABS. ANGL.; BIBL. 1 P. 1/2Article

High voltage DC V-t characteristics of long air gapsAIHARA, Y; TAKAHASHI, T.Electrical engineering in Japan. 1983, Vol 103, Num 4, pp 1-8, issn 0424-7760Article

FLASHOVER CHARACTERISTICS OF EXTREMELY LONG GAPS IN TRANSFORMER OIL UNDER NON-UNIFORM FIELD CONDITIONSKAMATA Y; KAKO Y.1980; I.E.E.E. TRANS. ELECTR. INSULAT.; USA; DA. 1980; VOL. 15; NO 1; PP. 18-26; BIBL. 11 REF.Article

Performance of rod-rod gaps in the presence of dust particles under lightning impulsesQURESHI, M. I; AL-ARAINY, A. A; MALIK, N. H et al.IEEE transactions on power delivery. 1991, Vol 6, Num 2, pp 706-714, issn 0885-8977, 9 p.Conference Paper

Influence of dust particles on DC discharges in symmetrical air gapsAL-ARAINY, A. A.European transactions on electrical power. 1997, Vol 7, Num 4, pp 275-280, issn 1430-144XArticle

A new calculation method of breakdown voltage-time characteristics of long air gapsSHINDO, T; SUZUKI, T.IEEE transactions on power apparatus and systems. 1985, Vol 104, Num 6, pp 1556-1563, issn 0018-9510Article

Assessment of air-density correction for practical electrode systemsBOUTLENDJ, M; ALLEN, N. L.European transactions on electrical power. 1996, Vol 6, Num 4, pp 267-274, issn 1430-144XArticle

Laser-guided discharge characteristics of long air gaps and observation of the discharge processAIHARA, Y; SHINDO, T; MIKI, M et al.Electrical engineering in Japan. 1993, Vol 113, Num 4, pp 66-77, issn 0424-7760Article

  • Page / 1