Pascal and Francis Bibliographic Databases

Help

Search results

Your search

kw.\*:("DEBITMETRE ELECTROMAGNETIQUE")

Document Type [dt]

A-Z Z-A Frequency ↓ Frequency ↑
Export in CSV

Publication Year[py]

A-Z Z-A Frequency ↓ Frequency ↑
Export in CSV

Discipline (document) [di]

A-Z Z-A Frequency ↓ Frequency ↑
Export in CSV

Language

A-Z Z-A Frequency ↓ Frequency ↑
Export in CSV

Author Country

A-Z Z-A Frequency ↓ Frequency ↑
Export in CSV

Results 1 to 25 of 181

  • Page / 8
Export

Selection :

  • and

ELECTROMAGNETIC FLOWMETER CALIBRATION FACILITIES.KETELSEN B.1974; IN: FLOW. MEAS. CONTROL IN SCI. IND. SYMP. 1. PROC.; PITTSBURGH, PA.; 1971; PITTSBURGH; INSTRUM. SOC. AM.; DA. 1974; PP. 755-761Conference Paper

MEASUREMENT OF DIFFERENTIAL FLOWRATES USING AN ELECTROMAGNETIC TRANSDUCERSANDERSON ML.sdTRANSDUCER'78. CONFERENCE (1978-00-00); GBR; S.L.; DA. S.D.; PP. 1-11Conference Paper

CAPTEUR DE DEBITMETRE ELECTROMAGNETIQUE POUR FLUX SOUS PRESSION AVEC UN SIGNAL DE SORTIE PROPORTIONNEL AU DEBITKANTOROVICH VB; RUBIN ID.1977; IZVEST. VYSSH. UCHEBN. ZAVED., PRIBOROSTR.; S.S.S.R.; DA. 1977; VOL. 20; NO 5; PP. 23-27; BIBL. 4 REF.Article

ETUDE DU BRUIT D'ELECTRODE D'UN TRANSDUCTEUR RESISTIF DE DEBITGUREVICH GG; KIRSHTEJN G KH; YARMOLA YU A et al.1974; MAGNIT. GIDRODINAM., LATV. S.S.R.; S.S.S.R.; DA. 1974; NO 3; PP. 131-135; BIBL. 8 REF.Article

INFLUENCE DE LA DISTRIBUTION DES VITESSES SUR LES INDICATIONS DES DEBIMTETRES AVEC UN CHAMP MAGNETIQUE INVERSEMENT PROPORTIONNEL A LA FONCTION-POIDSKORSUNSKIJ LM.1974; MAGNIT. GIDRODINAM., LATV. S.S.R.; S.S.S.R.; DA. 1974; NO 2; PP. 125-128; BIBL. 7 REF.Article

SENSOR DESIGN FOR AN ELECTROMAGNETIC FLOW-METERDESA SE; DESA E.1980; INDIAN J. PURE APPL. PHYS.; ISSN 0019-5596; IND; DA. 1980; VOL. 18; NO 5; PP. 351-353; BIBL. 5 REF.Article

KALIBRIERANLAGE FUER INDUKTIVE DURCHFLUSSMESSER GROSSER NENNWEITEN = INSTALLATION D'ETALONNAGE POUR DEBITMETRES INDUCTIFS DE GRANDES VALEURS NOMINALESFRUH KF.1980; RTP, REGELUNGSTECH. PRAX.; ISSN 0340-4730; DEU; DA. 1980; VOL. 22; NO 7; PP. 238-239Article

A CLOSED-LOOP ELECTROMAGNETIC FLOWMETERDE SA SE; DE SA E.1980; J. PHYS. E; ISSN 0022-3735; GBR; DA. 1980; VOL. 13; NO 2; PP. 233-235; BIBL. 3 REF.Article

PROJEKTIERUNGSFRAGEN BEIM EINSATZ MAGNETISCHINDUKTIVER DURCHFLUSSMESSER = PRECAUTIONS D'EMPLOI DES DEBIMETRES ELECTROMAGNETIQUESHOGREFE W.1979; RTP, REGELUNGSTECH. PRAX.; ISSN 0340-4730; DEU; DA. 1979; VOL. 21; NO 11; PP. 331-333Article

PROGRES RECENTS DANS LA TECHNIQUE DES DEBIMETRES ELECTRO-MAGNETIQUES ET ETAT ACTUEL DE LEURS NORMESITOH K; ASADA K.1975; J. SOC. INSTRUM. CONTROL ENGRS; JAP.; DA. 1975; VOL. 14; NO 11; PP. 815-827; BIBL. 20 REF.Article

DEVELOPMENT OF A BIOLECTRIC IMPEDANCE FLOWMETERVAN DE WATER JM; MOUNT BE; JACKSON GF et al.1972; SURG. FORUM; U.S.A.; DA. 1972; VOL. 23; PP. 158-160; (PROC. 28TH. ANN. SESS. FORUM FUNDAM. SURG. PROBL., 58TH. CLIN. CONGR. AM. COLL. SURG.; SAN FRANCISCO; 1972)Conference Paper

DEBITMETRE ELECTROMAGNETIQUE POUR CANAUX OUVERTSSARKISYAN MA.1972; IZVEST. VYSSH. UCHEBN. ZAVED., NEFT GAZ; S.S.S.R.; DA. 1972; VOL. 15; NO 6; PP. 50-51Serial Issue

PROJEKTIERUNGSFRAGEN BEIM EINSATZ MAGNETISCH-INDUKTIVER DURCHFLUSSMESSER = PROBLEMES PREALABLES A L'EMPLOI DES DEBITMETRES ELECTROMAGNETIQUESHOGREFE W.1979; RTP, REGELUNGSTECH. PRAX.; ISSN 0340-4730; DEU; DA. 1979; VOL. 21; NO 9; PP. 257-262; BIBL. 4 REF.Article

BREVET DEBITMETRE ELECTROMAGNETIQUE DE PRECISION1978; ; FRA; DA. 1978-06-16; FR/A1/2.368.018; DEP.76 31464/1976-10-14Patent

ETALONNAGE DES DEBITMETRES A CHAMP MAGNETIQUE HETEROGENEVAVILOV OS; VEL'T ID.1976; IZMERITEL. TEKH.; S.S.S.R.; DA. 1976; NO 8; PP. 41-43; BIBL. 4 REF.Article

SENSITIVITY OF THE ELECTROMAGNETIC FLOWMETER TO FLUID VELOCITY PROFILE.HAACKE AC.1974; IN: FLOW. MEAS. CONTROL IN SCI. IND. SYMP. 1. PROC.; PITTSBURGH, PA.; 1971; PITTSBURGH; INSTRUM. SOC. AM.; DA. 1974; PP. 735-743; BIBL. 9 REF.Conference Paper

TRANSCUTANEOUS BLOOD FLOW MEASUREMENT BY ELECTROMAGNETIC INDUCTIONKANAI H; YAMANO E; NAKAYAMA K et al.1974; I.E.E.E. TRANS. BIOMED. ENGNG; U.S.A.; DA. 1974; VOL. 21; NO 2; PP. 144-151; BIBL. 7REF.Serial Issue

A SIMPLIFIED METHOD FOR THE IN VITRO CALIBRATION OF ELECTROMAGNETIC FLOWMETERS = UNE METHODE SIMPLIFIEE POUR L'ETALONNAGE IN VITRO DES DEBITMETRES ELECTROMAGNETIQUESMARLON AM; ADAMS MH; BATES BL et al.1973; CARDIOVASCUL. RES.; G.B.; DA. 1973; VOL. 7; NO 2; PP. 290-296; BIBL. 11REF.Serial Issue

THE INSIDE STORY OF A NEW MAGNETIC FLOW CONVERTER.KEEBLE SGM.sdIN: TRANSDUCER 75 CONF.; LONDON; 1975; S.L.; DA. S.D.; PP. 1-13Conference Paper

Induktiver Durchflussmesser mit keramischer Auskleidung und kapazitivem Signalabgriff = Débitmètre inductif à revêtement céramique et détection capacitive du signal = Inductive flowmeter with ceramics coating and capacitive signal detectionAPPEL, E.Automatisierungstechnische Praxis. 1985, Vol 27, Num 4, pp 199-200, issn 0178-2320Article

MAGNETISCH-INDUKTIVE DURCHFLUSSMESSUNG IM BERGBAU = MAGNETIC-INDUCTIVE FLOW MEASUREMENT IN MINING = MESURE MAGNETOINDUCTIVE DE DEBIT DANS L'INDUSTRIE MINIEREHINZE G.1981; BERGBAU; ISSN 0373-2371; DEU; DA. 1981; VOL. 32; NO 10; PP. 639-641; BIBL. 3 REF.Article

FLOW CALIBRATION RIG1980; MEASUR. AND CONTROL; GBR; DA. 1980; VOL. 13; NO 2; PP. 51Article

MESSEINRICHTUNGEN FUER REAKTOREN MIT NATRIUMKUEHLUNG = DISPOSITIFS DE MESURE POUR REACTEURS REFROIDIS AU SODIUMBERGMANN W; HOTTMANN D.1975; A.T.M. MESSTECH. PRAXIS; DTSCH.; DA. 1975; NO 472; PP. 73-76Article

ANALYSIS OF THE PERFORMANCE OF THREE LARGE-ELECTRODE ELECTROMAGNETIC FLOWMETERSAL KHAZRAJI YA; BAKER RC.1979; J. PHYS. D; ISSN 0022-3727; GBR; DA. 1979; VOL. 12; NO 9; PP. 1423-1434; BIBL. 3 REF.Article

A REVIEW OF SOME APPLICATIONS OF ELECTROMAGNETIC FLOW MEASUREMENT.BAKER RC.1974; IN: FLOW. MEAS. CONTROL IN SCI. IND. SYMP. 1. PROC.; PITTSBURGH, PA.; 1971; PITTSBURGH; INSTRUM. SOC. AM.; DA. 1974; PP. 745-753; BIBL. 23 REF.Conference Paper

  • Page / 8