Pascal and Francis Bibliographic Databases

Help

Search results

Your search

kw.\*:("DEFIBRILLATOR")

Filter

A-Z Z-A Frequency ↓ Frequency ↑
Export in CSV

Document Type [dt]

A-Z Z-A Frequency ↓ Frequency ↑
Export in CSV

Publication Year[py]

A-Z Z-A Frequency ↓ Frequency ↑
Export in CSV

Discipline (document) [di]

A-Z Z-A Frequency ↓ Frequency ↑
Export in CSV

Language

A-Z Z-A Frequency ↓ Frequency ↑
Export in CSV

Author Country

A-Z Z-A Frequency ↓ Frequency ↑
Export in CSV

Results 1 to 25 of 4411

  • Page / 177
Export

Selection :

  • and

A DEFIBRILLATOR TROLLEY.JAMIESON MF.1976; EUROP. J. INTENSIVE CARE MED.; GERM.; DA. 1976; VOL. 2; NO 1; PP. 59Article

THE HALF-CYCLE SINUSOID AS AN ALTERNATIVE DEFIBRILLATING WAVEFORM IN LOW-ENERGY APPLICATIONS.MOORE TW; DIMEO FN; DUBIN SE et al.1977; ANN. BIOMED. ENGNG; U.S.A.; DA. 1977; VOL. 5; NO 2; PP. 157-163; BIBL. 10 REF.Article

NEW INTERFERENCE SENSING DEMAND PACEMAKER FUNCTIONS.BROWNLEE RR; TYERS GFO; NEFF PH et al.1978; I.E.E.E. TRANS. BIO-MED. ENGNG; U.S.A.; DA. 1978; VOL. 25; NO 3; PP. 264-269; BIBL. 19 REF.Article

USE OF AN AUTOMATED EXTERNAL DEFIBRILLATOR-PACEMAKER BY AMBULANCE STAFFJAGGARAO NSV; GRAINGER R; HEBER M et al.1982; LANCET (BR. ED.); ISSN 0140-6736; GBR; DA. 1982; NO 8289; PP. 73-75; BIBL. 8 REF.Article

THORACIC IMPEDANCE OF HUMAN SUBJECTS.MACHIN JW.1978; MED. BIOL. ENGNG COMPUTG; G.B.; DA. 1978; VOL. 16; NO 2; PP. 169-178; ABS. FR. ALLEM.; BIBL. 3 REF.Article

PHARMACOLOGIC AND PATHOLOGIC EFFECTS OF AN AUTOMATIC IMPLANTABLE DEFIBRILLATORDEEB GM; HARDESTY RL; THOMPSON ME et al.1981; TRANS.-AM. SOC. ARTIF. INTERN. ORGANS; ISSN 0066-0078; USA; DA. 1981; VOL. 27; PP. 1-6; BIBL. 4 REF.Conference Paper

DIGITAL CARDIAC DEFIBRILLATOR TESTERSUM CMA; DEWHURST DJ.1979; MED. BIOL. ENGNG COMPUTG; GBR; DA. 1979; VOL. 17; NO 6; PP. 710-714; BIBL. 6 REF.Article

DIELECTRIC BREAKDOWN OF HUMAN SKIN IN VIVOGRIMNES S.1983; MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING; ISSN 0140-0118; GBR; DA. 1983; VOL. 21; NO 3; PP. 379-381; BIBL. 9 REF.Article

SUCCESSFUL CONVERSION OF OUT-OF-HOSPITAL LIFE-THREATENING ARRHYTHMIAS WITH THE IMPLANTED AUTOMATIC DEFIBRILLATORMIROWSKI M; REID PR; MOWER MM et al.1982; AM. HEART J.; ISSN 0002-8703; USA; DA. 1982; VOL. 103; NO 1; PP. 147-148; BIBL. 4 REF.Article

Moderate sea states do not influence the application of an AED in rigid inflatable boatsDE VRIES, Wiebe; BIERENS, Joost J. L. M; MAAS, Martijn W. M et al.Resuscitation. 2006, Vol 70, Num 2, pp 247-253, issn 0300-9572, 7 p.Article

Trials of the automatic implantable defibrillator in manWATKINS, L. JR; MOWER, M. M; REID, P. R et al.Journal of thoracic and cardiovascular surgery. 1983, Vol 86, Num 3, pp 381-387, issn 0022-5223Article

Is there any room for shortening hands-off time further when using an AED?JOONG EUI RHEE; KIM, Taeyun; KIM, Kyuseok et al.Resuscitation. 2009, Vol 80, Num 2, pp 231-237, issn 0300-9572, 7 p.Article

Self-training in the use of automated external defibrillators : The same results for less moneyDE VRIES, Wiebe; SCHELVIS, Mark; RUSTEMEIJER, Ingrid et al.Resuscitation. 2008, Vol 76, Num 1, pp 76-82, issn 0300-9572, 7 p.Article

Annual rate of transvenous defibrillation lead defects in implantable cardioverter-defibrillators over a period of >10 yearsKLEEMANN, Thomas; BECKER, Torsten; DOENGES, Klaus et al.Circulation (New York, N.Y.). 2007, Vol 115, Num 19, pp 2474-2480, issn 0009-7322, 7 p.Article

Lessons from the failure and recall of an implantable cardioverter-defibrillatorHAUSER, Robert G; MARON, Barry J.Circulation (New York, N.Y.). 2005, Vol 112, Num 13, pp 2040-2042, issn 0009-7322, 3 p.Article

Socioeconomic disparities in the knowledge of basic life support techniquesWEINER, Scott G; KAPADIA, Tina; FAYANJU, Olaoluwa et al.Resuscitation. 2010, Vol 81, Num 12, pp 1652-1656, issn 0300-9572, 5 p.Article

Effects of AED device features on performance by untrained laypersonsMOSESSO, Vincent N; SHAPIRO, Alan H; STEIN, Karen et al.Resuscitation. 2009, Vol 80, Num 11, pp 1285-1289, issn 0300-9572, 5 p.Article

Performance of an automated external defibrillator during simulated rotor-wing critical care transportsSANG MO JE; JE SUNG YOU; TAE NYOUNG CHUNG et al.Resuscitation. 2011, Vol 82, Num 4, pp 454-458, issn 0300-9572, 5 p.Article

MORTALITY IN PATIENTS WITH IMPLANTED AUTOMATIC DEFIBRILLATORSMIROWSKI M; REID PR; WINKLE RA et al.1983; ANNALS OF INTERNAL MEDICINE; ISSN 0003-4819; USA; DA. 1983; VOL. 98; NO 5; PP. 585-588; BIBL. 16 REF.Article

DEFIBRILLATION RECOVERY CURVES FOR DIFFERENT ELECTRODE MATERIALSDAS DP; WEBSTER JG.1980; I.E.E.E. TRANS. BIO. MED. ENGNG; USA; DA. 1980; VOL. 27; NO 4; PP. 230-233; BIBL. 10 REF.Article

A RELIABLE MICROPROCESSOR-BASED DEFIBRILLATOR ANALYZERSHARMA VK; CHOPRA YC; BAJWA JS et al.1982; IEEE TRANS. INSTRUM. MEAS.; ISSN 0018-9456; USA; DA. 1982; VOL. 31; NO 1; PP. 28-31; BIBL. 6 REF.Article

LEAD SYSTEMS FOR INTERNAL VENTRICULAR FIBRILLATIONDEEB GM; GRIFFITH BP; THOMPSON ME et al.1981; CIRCULATION; ISSN 0009-7322; USA; DA. 1981; VOL. 64; NO 2; PP. 242-245; BIBL. 8 REF.Article

TRACEABLE CALIBRATION OF A CARDIAC DEFIBRILLATOR ENERGY METERSTOCKTON JR; SMITH RC.1981; MED. BIOL. ENG. COMPUT.; ISSN 0140-0118; GBR; DA. 1981; VOL. 19; NO 1; PP. 40-48; BIBL. 5 REF.Article

PROCEEDINGS: SECOND PURDUE CARDIAC DEFIBRILLATION CONFERENCE.1978; MED. INSTRUMENT.; U.S.A.; DA. 1978; VOL. 12; NO 1; PP. 10-69; BIBL. DISSEM.Article

BREVET 2.350.111 (A1) (77 13579). - 4 MAI 1977. APPAREIL DEFIBRILLATEUR POUR L'APPLICATION DE CHOCS ELECTRIQUES A CERTAINS MUSCLES.sdPatent

  • Page / 177