PARALLELENDMASSE MIT BEKANNTEN ISTMASSEN = JAUGES ETALONS A COTES EFFECTIVES CONNUESHAUSER K; KERNER M.1982; WERKSTATT BETR.; ISSN 0043-2792; DEU; DA. 1982; VOL. 115; NO 4; PP. 253-255; BIBL. 1 REF.Article

The use of reliability in the Taguchi method for the optimisation of the polishing ceramic gauge blockLIN, Tsann-Rong.International journal, advanced manufacturing technology. 2003, Vol 22, Num 3-4, pp 237-242, issn 0268-3768, 6 p.Article

ZUM THERMISCHEN VERHALTEN STABFOERMIGER LAENGENMASSVERKOERPERUNGEN. II = COMPORTEMENT THERMIQUE DES ETALONS DE MESURE DE LONGUEUR EN FORME DE BARRES. IINICOLAI E; KLOPP J.1982; FEINGERAETETECHNIK; ISSN 0014-9683; DDR; DA. 1982; VOL. 31; NO 5; PP. 202-204; BIBL. 4 REF.Article

AN AUTOMATIC COMPARATOR FOR SLIP GAUGE CALIBRATIONALDRED PJE.1981; PRECIS. ENG.; ISSN 0141-6359; GBR; DA. 1981; VOL. 3; NO 2; PP. 109-113; BIBL. 2 REF.Article

STEIGERUNG DER MESSGENAUIGKEIT DER ZWEIKOORDINATENMESSGERAETE DES VEB CARL ZEISS JENA DURCH KALIBRIERUNG MIT PARALLELENDMASSEN = L'AMELIORATION DE LA PRECISION DE MESURE DES MACHINES DE MESURE A DEUX COORDONNEES DE LA FIRME CARL ZEISS, IENA, PAR ETALONNAGE AU MOYEN DE CALES ETALONS A BORDS PARALLELESERBEN A; HULTZSCH E.1978; FEINGERAETETECHNIK; DDR; DA. 1978; VOL. 27; NO 7; PP. 295-297; ABS. RUS/ENG/FRE; BIBL. 4 REF.Article

PARALLELENDMASSE UND DEREN UEBERWACHUNG = CALES A FACES PARALLELES ET LEUR SURVEILLANCEWALTER F.1983; F & M. FEINWERKTECHNIK & MESSTECHNIK; ISSN 0340-1952; DEU; DA. 1983; VOL. 91; NO 3; PP. 139-140; ABS. ENGArticle

ENDMASSE, RATIONELL GEMESSEN. DATENERFASSUNG UND DATENVERARBEITUNG BIS ZUM AMTLICHEN PRUEFSCHEIN = MESURE RATIONNELLE DES CALES ETALONS. ENREGISTREMENT ET TRAITEMENT DES INFORMATIONS JUSQU'AU BULLETIN DE VERIFICATION OFFICIELPERROCHET JF; KERNER M; TOGGWEILER U et al.1978; V.D.I.-Z.; DEU; DA. 1978; VOL. 120; NO 21; PP. 996-999; ABS. ENGArticle

LAENGENUNTERSCHIED ZWISCHEN MECHANISCH AUFGESETZTEN UND ANGESCHOBENEN PARALLELENDMASSEN. = DIFFERENCE DE LONGUEURS ENTRE DES CALES ETALONS POSEES OU POUSSEES MECANIQUEMENTBOHME H; FISCHER W.1977; F.U.M.; DTSCH.; DA. 1977; VOL. 85; NO 2; PP. 72-74; BIBL. 6 REF.Article

Nouvelles méthodes d'étalonnage des comparateurs de cales étalons = New calibration method of gage block calibration benchesSCHATZ, B.Bulletin du Bureau national de métrologie. 1990, Num 80, pp 17-20, issn 0982-2232, 4 p.Article

SLIP GAUGE QUALITYKERNER M.1981; PRECIS. ENG.; ISSN 0141-6359; GBR; DA. 1981; VOL. 3; NO 2; PP. 114-118Article

PHASE CORRECTION IN THE INTERFEROMETRIC MEASUREMENT OF END STANDARDS.THWAITE EG.1978; METROLOGIA; ALLEM.; DA. 1978; VOL. 14; NO 2; PP. 53-62; BIBL. 14 REF.Article

LENGTH MEASUREMENT USING INFRARED TWO-WAVELENGTH HE-XE LASER INTERFEROMETERMATSUMOTO H.1982; REV. SCI. INSTRUM.; ISSN 0034-6748; USA; DA. 1982; VOL. 53; NO 5; PP. 641-643; BIBL. 14 REF.Article

METROLOGISCHE GRENZEN BEIM VERGLEICH VON ENDMASSEN UND STRICHMASSEN MIT WELLENLAENGENNORMALEN = LIMITES METROLOGIQUES DANS LA COMPARAISON ENTRE CALES ETALONS ET REGLES GRADUEES AVEC UN ETALON DE LONGUEUR D'ONDESCHMIDT K; TSCHIRNICH J.1980; FEINGERAETETECHNIK; ISSN 0014-9683; DDR; DA. 1980; VOL. 29; NO 2; PP. 85-87; BIBL. 6 REF.Article

ABSOLUTE KALIBRIERUNG VON STUFENENDMASSEN UND ENDMASSEN MIT EINEM ZWEI ACHSIGEN LASERINTERFEROMETER- KOMPARATOR = CONTROLE ABSOLU DE CALES ETALONS SIMPLES OU ETAGEES AVEC UN COMPARATEUR INTERFEROMETRIQUE LASER BIAXIALSCHUESSLER HH.1983; TM, TECHNISCHES MESSEN; ISSN 0171-8096; DEU; DA. 1983; VOL. 50; NO 5; PP. 191-196; ABS. ENG; BIBL. 22 REF.Article

LAENGENMESSUNG GROSSER PARALLELENDMASSE DURCH INTERFERENTIELLEN VERGLEICH MIT FABRY-PEROT-ETALONS = MESURE DE LA LONGUEUR DE GRANDES CALES A FACES PARALLELES PAR COMPARAISON INTERFEROMETRIQUE AVEC L'ETALON DE FABRY-PEROTSUSKA J.1983; FEINGERAETETECHNIK; ISSN 0014-9683; DDR; DA. 1983; VOL. 32; NO 5; PP. 211-213; BIBL. 5 REF.Article

Interferometers for calibration of length standards : Optical science and engineering in FinlandLASSILA, A; IKONEN, E; RISKI, K et al.Optical engineering (Bellingham. Print). 1995, Vol 34, Num 9, pp 2619-2622, issn 0091-3286Article

Gauge block interferometer with no wringing on base plateISHII, Y; SEINO, S.International journal of the Japan Society for Precision Engineering. 1996, Vol 30, Num 1, pp 83-84, issn 0916-782XArticle

Development of a new interferometric measurement system for determining the main characteristics of gauge blocksKURIYAMA, Y; YOKOYAMA, Y; ISHII, Y et al.CIRP annals. 2006, Vol 55, Num 1, pp 563-566, issn 0007-8506, 4 p.Conference Paper

Incertitudes liées à l'utilisation de plans références en silice lors des mesures interférentielles de cales à bouts plans parallèles = Errors introduced by using silica reference planes in interference measurements of gauges with parallel plane endsMICHEL, A.Bulletin d'Information du Bureau National de Métrologie. 1985, Vol 16, Num 62, pp 3-11, issn 0373-3815Article

DYNAMISCHES MESSVERFAHREN ZUR LAENGENBESTIMMUNG VON PARALLELENDMASSEN = METHODE DE MESURE DYNAMIQUE POUR LA DETERMINATION DES LONGUEURS DE CALES A BORDS PARALLELESPIELES H.1979; FEINGERAETETECHNIK; DDR; DA. 1979; VOL. 28; NO 1; PP. 11-13; BIBL. 5 REF.Article

Calibration of integrating sphere system designed for roughness correction in optical calibration of gauge blocksKANG, Chu-Shik; JAE WAN KIM; KIM, Jong-Ahn et al.Proceedings of SPIE, the International Society for Optical Engineering. 2007, pp 66720O.1-66720O.9, issn 0277-786X, isbn 978-0-8194-6820-8, 1VolConference Paper

A new method of noncontact gauge block calibration using the fringe counting technique: II. Experimental verificationIWASINSKA-KOWALSKA, O; DOBOSZ, M.Optics and laser technology. 2010, Vol 42, Num 1, pp 149-155, issn 0030-3992, 7 p.Article

Trend studies of standard and regular gauge block setsTAN, A; MILLER, J. R.Review of scientific instruments. 1991, Vol 62, Num 1, pp 233-237, issn 0034-6748, 5 p.Article

Burning of small crib ignition sources = Combustion d'un caisson à claire voie auquel on a mis le feuHOLMLUND, C.1988, 32 p., isbn 951-38-3273-2Report

A new method of non-contact gauge block calibration using a fringe-counting technique: I. Theoretical basisDOBOSZ, M; IWASINSKA-KOWALSKA, O.Optics and laser technology. 2010, Vol 42, Num 1, pp 141-148, issn 0030-3992, 8 p.Article