Pascal and Francis Bibliographic Databases

Help

Search results

Your search

kw.\*:("Prothrombin time")

Document Type [dt]

A-Z Z-A Frequency ↓ Frequency ↑
Export in CSV

Publication Year[py]

A-Z Z-A Frequency ↓ Frequency ↑
Export in CSV

Discipline (document) [di]

A-Z Z-A Frequency ↓ Frequency ↑
Export in CSV

Language

A-Z Z-A Frequency ↓ Frequency ↑
Export in CSV

Author Country

A-Z Z-A Frequency ↓ Frequency ↑
Export in CSV

Results 1 to 25 of 587

  • Page / 24
Export

Selection :

  • and

Survey of prothrombin time in National External Quality Assessment Scheme exercises (1980-87)POLLER, L; TABERNER, D. A; THOMSON, J. M et al.Journal of clinical pathology. 1988, Vol 41, Num 4, pp 361-364, issn 0021-9746Article

Standardization of the INR : How Good Is Your Laboratory's INR and Can It Be Improved?FAVALORO, Emmanuel J; ADCOCK, Dorothy M.Seminars in thrombosis and hemostasis. 2008, Vol 34, Num 7, pp 593-603, issn 0094-6176, 11 p.Article

A simple nomogram for the derivation of international normalised ratios for the standardisation of prothrombin timesPOLLER, L.Thrombosis and haemostasis. 1988, Vol 60, Num 1, pp 18-20, issn 0340-6245Article

Use of a centrifugal analyzer for a chromogenic prothrombin time, a chromogenic activated partial thrombolastin time and a kinetic fibrinoben assay in a routine hospital laboratoryDE METZ, M; VAN WERSCH, J. W. J.Haemostasis. 1987, Vol 17, Num 5, pp 254-259, issn 0301-0147Article

ICSH/ICTH recommendations for reporting prothrombin time in oral anticoagulant controlClinica chimica acta. 1985, Vol 146, Num 2-3, pp 231H-233H, issn 0009-8981Article

Prothrombin time proficiency testing: a robust grading methodYANGSOOK HAN; LAWSON, W. B; DODDS, W. J et al.Thrombosis and haemostasis. 1985, Vol 54, Num 3, pp 704-708, issn 0340-6245Article

Imprecision of prothrombin time monitoring of oral anticoagulation : a survey of hospital laboratoriesANSELL, J. E.American journal of clinical pathology. 1992, Vol 98, Num 2, pp 237-239, issn 0002-9173Article

A comprehensive evaluation of the performance of duplicate prothrombin time and activated partial thromboplastin time assaysDOUGLAS SCHEER, W; CATROU, P. G; LIPSCOMB, G. E et al.American journal of clinical pathology. 1986, Vol 85, Num 4, pp 456-462, issn 0002-9173Article

Application of mechanical impedance measurements to the study of dysfibrinogensSCHREIBER, W. E; SCHMER, G.The Journal of laboratory and clinical medicine. 1984, Vol 104, Num 4, pp 494-500, issn 0022-2143Article

Prophylactic correction of the international normalized ratio in neurosurgery: a brief review of a brief literatureWEST, Kelly L; ADAMSON, Cory; HOFFMAN, Maureane et al.Journal of neurosurgery. 2011, Vol 114, Num 1, pp 9-18, issn 0022-3085, 10 p.Article

An assessment of the utility of unselected coagulation screening in general hospital practiceMCHUGH, Johnny; HOLT, Carloyn; O'KEEFFE, Denis et al.Blood coagulation & fibrinolysis. 2011, Vol 22, Num 2, pp 106-109, issn 0957-5235, 4 p.Article

Effect of prothrombin time outlier exclusion rules on ISI calibration in multicentre studiesVAN DEN BESSELAAR, A. M. H. P; CHANTARANGKUL, V; TRIPODI, A et al.Thrombosis research. 2010, Vol 125, Num 6, pp 523-528, issn 0049-3848, 6 p.Article

Calibration of BCT/441, the ICSH reference preparation for thromboplastinTHOMSON, J. M; DARBY, K. V; POLLER, L et al.Thrombosis and haemostasis. 1986, Vol 55, Num 3, pp 379-382, issn 0340-6245Article

Le temps de prothrombine revisité 70 ans après : Angiologie-hémostase = Seventy years later : prothrombin time revisitedREBER, Guido; BOEHLEN, Francoise.Revue médicale suisse. 2008, Vol 4, Num 143, pp 350-353, issn 1660-9379, 4 p.Article

A simple system for the derivation of international normalized ratios for the reporting of prothrombin time results with North American thromboplastin reagentsPOLLER, L; HIRSH, J.American journal of clinical pathology. 1989, Vol 92, Num 1, pp 124-126, issn 0002-9173, 3 p.Article

ICSH/ICTH recommendations for reporting prothrombin time in oral anticoagulant controlJournal of clinical pathology. 1985, Vol 38, Num 2, pp 133-134, issn 0021-9746Article

STABILITY OF INTERNATIONAL REFERENCE THROMBOPLASTINSVAN DEN BESSELAAR AMHP; VAN HALEM VISSER LP; LOELIGER EA et al.1980; BRIT. J. HAEMATOL.; GBR; DA. 1980; VOL. 45; NO 1; PP. 153-160; BIBL. 9 REF.Article

NEW ALTERNATIVE SCHEME FOR HUMAN BLOOD COAGULATION.HONORATO R; IVANOVIC N; NOVOA E et al.1976; THROMBOSIS RES.; G.B.; DA. 1976; VOL. 8; NO 6; PP. 837-841; BIBL. 5 REF.Article

PROTHROMBIN QUICK. A NEWLY IDENTIFIED DYSPROTHROMBINEMIA.OWEN CA JR; HENRIKSEN RA; MCDUFFIE FC et al.1978; MAYO CLIN. PROC.; U.S.A.; DA. 1978; VOL. 53; NO 1; PP. 29-33; BIBL. 40 REF.Article

AN AUTOMATIC METHOD FOR THROMBOTEST ON THE "COBAS BIO" CENTRIFUGAL ANALYSERLUND KARLSEN R; VISDAL A; STENSBERG A et al.1982; SCAND. J. CLIN. LAB. INVEST.; ISSN 0036-5513; NOR; DA. 1982; VOL. 42; NO 8; PP. 647-649; BIBL. 2 REF.Article

QUALITAETSSICHERUNG DER PROTHROMBIN-ZEITBESTIMMUNG IM MITTLEREN LABOR = QUALITE DELA DETERMINATION DU TEMPS DE PROTHROMBINE DANS UN LABORATOIRE MOYENWILLE E; BUTTLER M.1978; Z. ALLG.-MED.; DEU; DA. 1978; VOL. 54; NO 29; PP. 1478-1481; BIBL. 9 REF.Article

Improving the harmonisation of the International Normalized Ratio (INR): time to think outside the box?FAVALORO, Emmanuel J; MCVICKER, Wendy; HAMDAM, Sayed et al.Clinical chemistry and laboratory medicine. 2010, Vol 48, Num 8, pp 1079-1090, issn 1434-6621, 12 p.Article

The clinical significance of differences between point-of-care and laboratory INR methods in over-anticoagulated patientsLAWRIE, A. S; HILLS, J; LONGAIR, I et al.Thrombosis research. 2012, Vol 130, Num 1, pp 110-114, issn 0049-3848, 5 p.Article

Collection of Blood Specimens by Venipuncture for Plasma-Based Coagulation Assays: Necessity of a Discard TubeRAIJMAKERS, Maarten T. M; MENTING, Carolien H. F; VADER, Huib L et al.American journal of clinical pathology. 2010, Vol 133, Num 2, pp 331-335, issn 0002-9173, 5 p.Article

A national field study of quality assessment of coaguchek point-of-care testing prothrombin time monitorsMEIJER, Piet; KLUFT, Cornelis; POLLER, Leon et al.American journal of clinical pathology. 2006, Vol 126, Num 5, pp 756-761, issn 0002-9173, 6 p.Article

  • Page / 24