Pascal and Francis Bibliographic Databases

Help

Search results

Your search

kw.\*:("THERMAL INERTIA")

Document Type [dt]

A-Z Z-A Frequency ↓ Frequency ↑
Export in CSV

Publication Year[py]

A-Z Z-A Frequency ↓ Frequency ↑
Export in CSV

Discipline (document) [di]

A-Z Z-A Frequency ↓ Frequency ↑
Export in CSV

Language

A-Z Z-A Frequency ↓ Frequency ↑
Export in CSV

Author Country

A-Z Z-A Frequency ↓ Frequency ↑
Export in CSV

Origin

A-Z Z-A Frequency ↓ Frequency ↑
Export in CSV

Results 1 to 25 of 444

  • Page / 18
Export

Selection :

  • and

THERMAL INERTIA MAPPING: A NEW VIEW OF THE EARTH.PRICE JC.1977; J. GEOPHYS. RES.; U.S.A.; DA. 1977; VOL. 82; NO 18; PP. 2582-2590; BIBL. 12 REF.Article

LE CONCEPT D'INERTIE THERMIQUE ET L'HUMIDITE DES SOLSBONN F; BERNIER M; BROCHU R et al.sdCANADIAN SYMPOSIUM ON REMOTE SENSING. 5/1978/VICTORIA BC; CAN; DA. S.D.; PP. 454-459; ABS. ENG; BIBL. 17 REF.Conference Paper

L'ENERGIE SOLAIRE DANS L'HABITAT. VENTILATION DE L'HABITAT = SOLAR ENERGY IN DWELLINGS. HOUSE VENTILATIONCARDONNEL C.1981; CHAUD, FROID PLOMBERIE; ISSN 0009-2010; FRA; DA. 1981; NO 418; PP. 91-99Article

BREVET 2.319.865 (A1) (76 22997). - 28 JUILLET 1976. PERFECTIONNEMENTS A LA CONSTRUCTION MODULAIRE DE FOURS.sdPatent

BREVET 2.303.253 (A1) (75 06742). - 4 MARS 1975. FOUR-TUNNEL REFROIDI ET AVEC EFFET DE SOL.sdPatent

A SIMPLE ALGORITHM TO ESTIMATE THE EFFECTIVE REGIONAL ATMOSPHERIC PARAMETERS FOR THERMAL-INERTIA MAPPINGWATSON K; HUMMER MILLER S.1981; REMOTE SENS. ENVIRON.; ISSN 0034-4257; USA; DA. 1981; VOL. 11; NO 6; PP. 455-462; BIBL. 1 P.Article

THERMAL PROPERTIES OF 433 EROSLEBOFSKY LA; RIEKE GH.1979; ICARUS; USA; DA. 1979; VOL. 40; NO 2; PP. 297-308; BIBL. 30 REF.Article

BREVET FOUR CONTINU A TRANSPORTEUR CONTINU A FAIBLE INERTIE THERMIQUE1979; ; FRA; DA. 1979-05-11; FR/A1/2.402.849; DEP.77 27546/1977-09-07Patent

DETERMINATION DU FACTEUR D'INERTIE THERMIQUE DES MICROTHERMOCOUPLESMAL'GUN MM; SOBOLEV MD.1977; PRIBORY TEKH. EKSPER.; S.S.S.R.; DA. 1977; NO 3; PP. 197-199; BIBL. 6 REF.Article

A COMPARISON OF THE THERMAL AND RADAR CHARACTERISTICS OF MARSJAKOSKY BM; MUHLEMAN DO.1981; ICARUS; ISSN 0019-1035; USA; DA. 1981; VOL. 45; NO 1; PP. 25-38; BIBL. 2 P.Article

ENERGY CONSERVATION DESIGN GUIDELINES: INCLUDING MASS AND INSULATION IN BUILDING WALLSDEXTER ME.1980; A.S.H.R.A.E. J.; USA; DA. 1980; VOL. 22; NO 3; PP. 35-38; BIBL. 4 REF.Article

TWO-DIMENSIONAL MODEL VARIABILITY IN THERMAL INERTIA SURVEYSPRATT DA.1980; REMOTE SENS. ENVIRON.; ISSN 0034-4257; USA; DA. 1980; VOL. 9; NO 4; PP. 325-338; BIBL. 21 REF.Article

BREVET BRULEUR RADIANT A FAIBLE INERTIE THERMIQUE1979; ; FRA; DA. 1979-05-11; FR/A1/2.402.831; DEP.77 27450/1977-09-12Patent

SURFACE PROPERTIES OF ANCIENT CRATERED TERRAIN IN THE NORTHERN HEMISPHERE OF MARSZIMBELMAN JR; GREELEY R.1982; JOURNAL OF GEOPHYSICAL RESEARCH; ISSN 0022-1406; USA; DA. 1982; VOL. 87; NO B12; PP. 10181-10189; BIBL. 19 REF.Article

IMAGE REGISTRATION FOR THERMAL INERTIA MAPPING, ITS POTENTIAL USE FOR MAPPING OF SOIL MOISTURE AND GEOLOGY IN AUSTRALIAPRATT DA; ELLYETT CD.1978; INTERNATIONAL SYMPOSIUM ON REMOTE SENSING OF ENVIRONMENT. 12/1978-04-20/MANILLE; USA; ANN ARBOR, MI: ENVIRONMENTAL RESEARCH INSTITUTE OF MICHIGAN; DA. 1978; VOL. 2; PP. 1207-1217; BIBL. 13 REF.Conference Paper

"TELL-US" A COMBINED SURFACE TEMPERATURE, SOIL MOISTURE AND EVAPORATION MAPPING APPROACHROSEMA A; BIJLEVELD JH; REINIGER P et al.1978; INTERNATIONAL SYMPOSIUM ON REMOTE SENSING OF ENVIRONMENT. 12/1978-04-20/MANILLE; USA; ANN ARBOR, MI: ENVIRONMENTAL RESEARCH INSTITUTE OF MICHIGAN; DA. 1978; VOL. 3; PP. 2267-2276; BIBL. 9 REF.Conference Paper

INERTIE THERMIQUE DE PERLITE ET CRITERES DE POLYMERISATION DANS LES PORES DE LA CHARGE DANS LE PROCESSUS DE PREPARATION DE POLYMERES CHARGESTONOYAN AO; SURKOV NF; PAPOYAN AT et al.1982; VYSOKOMOLEK. SOEDIN., KRATK. SOOBSHCH., B; SUN; DA. 1982; VOL. 24; NO 3; PP. 218-222; BIBL. 5 REF.Article

AN INSTRUMENT FOR MEASURING THERMAL INERTIA IN THE FIELDMARSH SE; SCHIELDGE JP; KAHLE AB et al.1982; PHOTOGRAMM. ENG. REMOTE SENSING; ISSN 0099-1112; USA; DA. 1982; VOL. 68; NO 4; PP. 605-607; BIBL. 4 REF.Article

LA CLIMATISATION ESTIVALE: DES MOYENS NATURELS POUR EVITER LE RECOURS A UNE CLIMATISATION COUTEUSE = SUMMER AIR CONDITIONNING: NATURAL WAY FOR AVOIDING AN EXPENSIVE INSTALLATIONBERGER X; DESLANDES J.1980; CAH. TECH. BATIM.; FRA; DA. 1980; NO 28; PP. 83-88Article

THE EFFECTS OF NONIDEAL SURFACES IN THE DERIVED THERMAL PROPERTIES OF MARSJAKOSKY BM.1979; J. GEOPHYS. RES.; USA; DA. 1979; VOL. 84; NO B14; PP. 8252-8262; BIBL. 37 REF.Article

INFLUENCE OF CONSTRUCTIONAL PARAMETERS OF BUILDINGS ON THEIR THERMAL BEHAVIOUR DURING HEATING OPERATIONMORALIJSKI E.1976; KHIDROL. I METEOROL.; BALG.; DA. 1976; VOL. 25; NO 3; PP. 13-22; ABS. RUSSE ANGL.; BIBL. 5 REF.Article

BREVET 2.347.663 (A1) (76 10454). - 9 AVRIL 1976. PERFECTIONNEMENTS AUX CAPTEURS DE TEMPERATURE ET A LEURS PROCEDES DE FABRICATION.sdPatent

ANALISI COMPARATIVA DEI METODI DI CALCOLO DEI CARICHI TERMICI ESTIVI. ASHRAE (FUZIONI DI TRASFERIMENTO) E CARRIER (PIZZETTI) = COMPARATIVE STUDY OF HEAT REQUIREMENTS IN SUMMER: ASHRAE METHOD (TRANSFER FUNCTION) AND CARRIER METHOD (PIZZETTI) = ANALYSE COMPARATIVE DES CHARGES THERMIQUES EN ETE: METHODE ASHRAE (FONCTIONS DE TRANSFERT) ET METHODE CARRIER (PIZZETTI)NATALE R; PORTOSO D.1981; COND. ARIA, RISCALD., REFRIG.; ISSN 0373-7772; ITA; DA. 1981; VOL. 25; NO 3; PP. 231-236Article

L'INERZIA TERMICA DELLE PARETI PERIMETRALI DEGLI EDIFICI E IL RISPARMIO ENERGETICO = THERMAL MASS OF OUTSIDE WALLS OF BUILDINGS AND ENERGY CONSERVATION = L'INERTIE THERMIQUE DES PAROIS EXTERIEURES ET LES ECONOMIES D'ENERGIEGINI M.1981; COND. ARIA, RISCALD., REFRIG.; ISSN 0373-7772; ITA; DA. 1981; VOL. 25; NO 2; PP. 123-128; ABS. FRE/ENG/GERArticle

A TECHNICAL REVIEW OF THE "M" FACTOR CONCEPTGODFREY RD; WILKES KE; LAVINE AG et al.1980; A.S.H.R.A.E. J.; USA; DA. 1980; VOL. 22; NO 3; PP. 47-50; BIBL. 10 REF.Article

  • Page / 18